Floor Mount Bi-Block OVTZ450 Monoblock Unit
Click Image for Gallery
Description:
Unit Model: OVTZ450
- Electronic control panel.
- Expansion device with thermal expansion valve.
- Solid core filter on liquid line.
- Pre-arrangement for room lighting connection and for door switch connection.
- Cable for door heater connection on all low temperature units.
- All units are equipped with a fixed calibration low pressure switch and high pressure switch, in accordance with the “Pressure Equipment Directive” 97/23/EC.
- All the units are supplied with a remote control panel already connected to the unit through a 5 m long cable (on request we could supply different lengths up to 20 m).
- Direct drainage of condensate.
- Drain heater.
- Condensing unit installation on the external floor of the cold room as well as evaporator installation on the ceiling inside the cold room.
- Sight glass.
- Solenoid valve on the liquid line in the forms 3I3-3I5 and in all models OVFR. On request it is available also in the models of the Forms 1I2-1I3-2I2-2I3.
- All units are supplied with a liquid receiver with safety valve, in accordance with the “Pressure Equipment Directive” 97/23/EC.
- Oil separator on discharge line in the models OVFR.
- Pressure regulating valve on suction line in the models OVFR.
- Liquid separator on suction line.
- Connection pipes couplings between condensing unit and evaporator have been realized without unions or weld neck flanges.
- Crankcase heater of compressor.
- Condenser fan pressure switch.
- Units suitable for external installation. Units recommended for use at ambient temperatures higher than 10°C. If units are mounted in Ambient temperature lower than 10°C, some accessories are needed.
- Cover to protect the unit against the bad weather.
Technical Data :
Condenser:
- Form: 1I2
- Fin pitch: 2,1
- Fans: 1x400
- Fan absorption: 1x160
- Airflow: 3950
Evaporator:
- Form: EVC2X350A
- Fin pitch: 7
- Fans: 2x350
- Fan absorption: 2x140
- Airflow: 4310
- Air-throw: 14
Refrigerating capacity (W) - Room volume (m³)
Cold room temperature: - 18 °C
Ambient temperature: + 25°C
- W: 4352
- m³: 90
Ambient temperature: + 32°C
- W: 3811
- m³: 65
Ambient temperature: + 43°C
- W: 2990
- m³: 36
Cold room temperature: - 22 °C
Ambient temperature: + 25°C
- W: 3760
- m³: 71
Ambient temperature: + 32°C
- W: 3242
- m³: 50
Ambient temperature: + 43°C
- W: 2501
- m³: 25
Cold room temperature: - 25 °C
Ambient temperature: + 25°C
- W: 3336
- m³: 58
Ambient temperature: + 32°C
- W: 2904
- m³: 42
Ambient temperature: + 43°C
- W: 2198
- m³: 20